상세설명
                
    
KVT-3000F
Vortex flowmeter - Flange type
Specification
 
Model
 
KVT-3000F
  
Size 
15 ~ 300mm  
Process connection 
Flange type(KS, ANSI, DIN)  
Accuracy 
Liquid : ±0.7% of reading, Gas, steam : ±1.0% of reading   
Measuring range 
1.6  ~ 540,000 kg/h  
Repeatablilty 
±0.2% of reading  
temperature 
-40~350℃(standard)  
Ambient Temperature 
-25~60℃  
Pressure 
78Kg/cm2(Max.)  
Power supply 
DC 12~32V  
Display 
Flowrate (6-digit)   
Totalizer (8-digit)   
2line LCD  
Output 
Analog : DC 4~20mA(Passive)   
Pulse : Scale pulse  
Protection class 
IP65   
Communication 
HART or RS-485(MODBUS)  
Special Function 
   
Option 
Temperature, Pressure compensation   
Temperature : PT1000Ω   
Pressure : 0 ~30mV DC  
Dimension
 
(mm)
 
Inner diameter 
 
Length L 
 
Height H 
  
D1(mm)
 
(mm)
 
(mm)
  
25
 
25
 
170
 
460
  
32
 
32
 
170
 
460
  
40
 
40
 
190
 
460
  
50
 
50
 
190
 
475
  
65
 
65
 
220
 
488
  
80
 
80
 
220
 
510
  
100
 
100
 
240
 
530
  
125
 
125
 
260
 
560
  
150
 
150
 
280
 
585
  
200
 
200
 
300
 
645
  
250
 
250
 
360
 
710
  
300
 
300
 
400
 
770
  
DRAWING

FLOW RANGE
Water & Gas Flow Range
 
 
Size(mm)
 
Water
 
Normal pressure and temperature air(NPT Air)
  
standard measuring range(m3/h)
 
standard measuring range(m3/h)
  
15 
0.8 ∼ 6 
6 ∼ 40  
20 
1 ∼ 8 
8 ∼ 50  
25 
1.5 ~ 25 
10 ~ 80  
32 
1.7 ~ 14 
16 ~ 120  
40 
2.5 ~ 30 
25 ~ 200  
50 
3 ~ 50 
30 ~ 300  
65 
5 ~ 80 
50 ~ 500  
80 
8 ~ 120 
80 ~ 800  
100 
12 ~ 200 
120 ~ 1200  
125 
20 ~ 300 
160 ~ 1600  
150 
30 ~ 400 
250 ~ 2500  
200 
50 ~ 800 
400 ~ 4000  
250 
80 ~ 1200 
600 ~ 6000  
300 
100 ~ 1600 
1000 ~ 10000  
 
 
Saturated Steam Flow Range
 
 
SIZE
 
Max. Flow Range (kg/h)
  
mm
 
inch
 
1KG/CM2.G
 
2KG/CM2.G
 
4KG/CM2.G
 
6KG/CM2.G
 
8KG/CM2.G
 
10KG/CM2.G
  
15 
1/2” 
3 ∼ 35 
4 ∼ 52 
5 ∼ 83 
6 ∼ 114 
7 ∼ 145 
8 ∼ 176  
20 
¾” 
6 ∼ 63 
7 ∼ 92 
10 ∼ 149 
11 ∼ 204 
13 ∼ 259 
14 ∼ 313  
25 
1” 
10 ∼ 93 
12 ∼ 144 
15 ∼ 232 
18 ∼ 319 
20 ∼ 405 
22 ∼ 490  
32 
1 2/4" 
16 ∼ 162 
20 ∼ 232 
25 ∼ 381 
30 ∼ 523 
33 ∼ 663 
37 ∼ 803  
40 
1-1/2” 
23 ∼ 305 
28 ∼ 444 
36 ∼ 715 
42 ∼ 980 
47 ∼ 1244 
52 ∼ 1505  
50 
2” 
36 ∼ 476 
44 ∼ 694 
56 ∼ 1117 
66 ∼ 1532 
74 ∼ 1944 
82 ∼ 2352  
65 
2-1/2”” 
62 ∼ 805 
75 ∼ 1173 
95 ∼ 1889 
111 ∼ 2590 
126 ∼ 3285 
138 ∼ 3976  
80 
3” 
94 ∼ 1220 
114 ∼ 1777 
144 ∼ 2861 
169 ∼ 3923 
190 ∼ 4977 
210 ∼ 6023  
100 
4” 
147 ∼ 1906 
178 ∼ 2777 
226 ∼ 4471 
264 ∼ 6130 
298 ∼ 7776 
328 ∼ 9411  
125 
5” 
230 ∼ 2979 
278 ∼ 4339 
353 ∼ 6987 
414 ∼ 9579 
466 ∼ 12515 
512 ∼ 14704  
150 
6” 
332 ∼ 4289 
401 ∼ 6248 
509 ∼ 10061 
596 ∼ 13794 
671 ∼ 17497 
738 ∼ 21174  
200 
8” 
591 ∼ 7626 
713 ∼ 11108 
905 ∼ 17887 
1059 ∼ 24523 
1193 ∼ 31107 
1313 ∼ 37644  
250 
10” 
923 ∼ 11916 
1114 ∼ 17356 
1414 ∼ 27948 
1656 ∼ 38317 
1865 ∼ 48605 
2051 ∼ 58819  
300 
12” 
1329 ∼ 17159 
1604 ∼ 24993 
2036 ∼ 40245 
2384 ∼ 55177 
2685 ∼ 69991 
2954 ∼ 84699  
 
Model Selection Guide

Installation

 
                KVT-3000F
Vortex flowmeter - Flange type
Specification
| Model | KVT-3000F | 
| Size | 15 ~ 300mm | 
| Process connection | Flange type(KS, ANSI, DIN) | 
| Accuracy | Liquid : ±0.7% of reading, Gas, steam : ±1.0% of reading | 
| Measuring range | 1.6 ~ 540,000 kg/h | 
| Repeatablilty | ±0.2% of reading | 
| temperature | -40~350℃(standard) | 
| Ambient Temperature | -25~60℃ | 
| Pressure | 78Kg/cm2(Max.) | 
| Power supply | DC 12~32V | 
| Display | Flowrate (6-digit) | 
| Totalizer (8-digit) | |
| 2line LCD | |
| Output | Analog : DC 4~20mA(Passive) | 
| Pulse : Scale pulse | |
| Protection class | IP65 | 
| Communication | HART or RS-485(MODBUS) | 
| Special Function | |
| Option | Temperature, Pressure compensation | 
| Temperature : PT1000Ω | |
| Pressure : 0 ~30mV DC | 
Dimension
| (mm) | Inner diameter | Length L | Height H | 
| D1(mm) | (mm) | (mm) | |
| 25 | 25 | 170 | 460 | 
| 32 | 32 | 170 | 460 | 
| 40 | 40 | 190 | 460 | 
| 50 | 50 | 190 | 475 | 
| 65 | 65 | 220 | 488 | 
| 80 | 80 | 220 | 510 | 
| 100 | 100 | 240 | 530 | 
| 125 | 125 | 260 | 560 | 
| 150 | 150 | 280 | 585 | 
| 200 | 200 | 300 | 645 | 
| 250 | 250 | 360 | 710 | 
| 300 | 300 | 400 | 770 | 
DRAWING

FLOW RANGE
Water & Gas Flow Range
| Size(mm) | Water | Normal pressure and temperature air(NPT Air) | 
| standard measuring range(m3/h) | standard measuring range(m3/h) | |
| 15 | 0.8 ∼ 6 | 6 ∼ 40 | 
| 20 | 1 ∼ 8 | 8 ∼ 50 | 
| 25 | 1.5 ~ 25 | 10 ~ 80 | 
| 32 | 1.7 ~ 14 | 16 ~ 120 | 
| 40 | 2.5 ~ 30 | 25 ~ 200 | 
| 50 | 3 ~ 50 | 30 ~ 300 | 
| 65 | 5 ~ 80 | 50 ~ 500 | 
| 80 | 8 ~ 120 | 80 ~ 800 | 
| 100 | 12 ~ 200 | 120 ~ 1200 | 
| 125 | 20 ~ 300 | 160 ~ 1600 | 
| 150 | 30 ~ 400 | 250 ~ 2500 | 
| 200 | 50 ~ 800 | 400 ~ 4000 | 
| 250 | 80 ~ 1200 | 600 ~ 6000 | 
| 300 | 100 ~ 1600 | 1000 ~ 10000 | 
Saturated Steam Flow Range
| SIZE | Max. Flow Range (kg/h) | ||||||
| mm | inch | 1KG/CM2.G | 2KG/CM2.G | 4KG/CM2.G | 6KG/CM2.G | 8KG/CM2.G | 10KG/CM2.G | 
| 15 | 1/2” | 3 ∼ 35 | 4 ∼ 52 | 5 ∼ 83 | 6 ∼ 114 | 7 ∼ 145 | 8 ∼ 176 | 
| 20 | ¾” | 6 ∼ 63 | 7 ∼ 92 | 10 ∼ 149 | 11 ∼ 204 | 13 ∼ 259 | 14 ∼ 313 | 
| 25 | 1” | 10 ∼ 93 | 12 ∼ 144 | 15 ∼ 232 | 18 ∼ 319 | 20 ∼ 405 | 22 ∼ 490 | 
| 32 | 1 2/4" | 16 ∼ 162 | 20 ∼ 232 | 25 ∼ 381 | 30 ∼ 523 | 33 ∼ 663 | 37 ∼ 803 | 
| 40 | 1-1/2” | 23 ∼ 305 | 28 ∼ 444 | 36 ∼ 715 | 42 ∼ 980 | 47 ∼ 1244 | 52 ∼ 1505 | 
| 50 | 2” | 36 ∼ 476 | 44 ∼ 694 | 56 ∼ 1117 | 66 ∼ 1532 | 74 ∼ 1944 | 82 ∼ 2352 | 
| 65 | 2-1/2”” | 62 ∼ 805 | 75 ∼ 1173 | 95 ∼ 1889 | 111 ∼ 2590 | 126 ∼ 3285 | 138 ∼ 3976 | 
| 80 | 3” | 94 ∼ 1220 | 114 ∼ 1777 | 144 ∼ 2861 | 169 ∼ 3923 | 190 ∼ 4977 | 210 ∼ 6023 | 
| 100 | 4” | 147 ∼ 1906 | 178 ∼ 2777 | 226 ∼ 4471 | 264 ∼ 6130 | 298 ∼ 7776 | 328 ∼ 9411 | 
| 125 | 5” | 230 ∼ 2979 | 278 ∼ 4339 | 353 ∼ 6987 | 414 ∼ 9579 | 466 ∼ 12515 | 512 ∼ 14704 | 
| 150 | 6” | 332 ∼ 4289 | 401 ∼ 6248 | 509 ∼ 10061 | 596 ∼ 13794 | 671 ∼ 17497 | 738 ∼ 21174 | 
| 200 | 8” | 591 ∼ 7626 | 713 ∼ 11108 | 905 ∼ 17887 | 1059 ∼ 24523 | 1193 ∼ 31107 | 1313 ∼ 37644 | 
| 250 | 10” | 923 ∼ 11916 | 1114 ∼ 17356 | 1414 ∼ 27948 | 1656 ∼ 38317 | 1865 ∼ 48605 | 2051 ∼ 58819 | 
| 300 | 12” | 1329 ∼ 17159 | 1604 ∼ 24993 | 2036 ∼ 40245 | 2384 ∼ 55177 | 2685 ∼ 69991 | 2954 ∼ 84699 | 
Model Selection Guide

Installation


 
                                            