* DEESYS Current transducers have good linearity and low ripple output.
The elements are totally isolated among input, output, power and
others to case.
* This ampere transducer provide proportional DC current and
voltage output which are not influence by any load resistance,
even under very low load condition, accurate output is available with quick
response.
* Transducers are designed to respond to the current value of input
but calibrated to root mean square (RMS) reading of pure sinusoid.
Head
Specification
Auxiliary power
AC 110/220V(±10%), 50/60㎐(1.5VA)
Input burden
Less than current 0.5VA, Voltage 0.6VA
Input over capability
Current rated : 1.2 In continuous 2 In 10sec 10 In 3sec Voltage rated : 1.2Vn continuous
Response
Less than 400ms, step change 0~95%
Output ripple
Ripple less than 0.5%Ro peak-peak.(span)
Operating temperature range
-10℃ to + 55℃
Operating humidity
0~99%, non-condensing
Calibrate adjustment
±1% minimum
Zero adjustment
±1% minimum
External magnetic field
Less than 0.01% 100AT/1M center
Dielectric strength
Terminal to case : 4000V AC rms 1minute Input to output : 2000V AC rms 1 minute
Output load
DC current mode : max 10V drop DC voltage mode : max 5mA drive