신품 판매중
전원공급기 - EAB-100
가격 가격협의
모델명 EAB-100
제품분류 전기/계측
업체명 삼성종합계측기
전화번호 0504-0667-9395
등록일 23.02.07
상세설명

 Capacity : 1KVA - 6KVA

· Built - in input active Power Factor Correction circuit (PF > 0.97), and be provided with large input voltage range 90 - 264V
· Enhanced ability to parallel or link with several units to expand capacity or form three phases output
· Adjustable AC output voltage 0 - 300V / frequency 40 - 1000HZ
· Large 240 X 64 Graphic LCD display
· Waveform distortion less than 1% on resistance load
· Enhanced crest factor. The rate is up to 3 : 1 at rating current output
· Fast recovering time, 0.4 milliseconds
· Line and load regulation maintains the output voltage within 0.5% of setting
· Programmable 50 memories and 9 steps per memory, for interconnection between each step to simulate different test conditions of the DUT
· Auto loop cycle, up to 999900 cycles
· For Aging or Life test on DUT, the user able to change the timer either in second, minute or hour
· Unique regulation function in providing capability to turn on high inrush current loads such as motors and compressors
· Capable to withstand inrush current up to 4 times of rated current and able to maintain 1000ms without protection
· Over Current Fold Back Mode (Response time < 1400mSec)
· Optional PLC remote interface control, including TEST / RESET and recall 7 memories quick output
· Built - in PLC remote output interface
· Protections and alerts for over current, short circuit, over voltage, over power, over temperature and reverse current
· Front panel software calibration
· Capable to set the starting angle, voltage dips, short interruptions and voltage variations to meet test application of IEC61000 - 4 - 11
· Adjust voltage / frequency setting via Rotary Knob when output is turn ON
· Optional GPIB, RS232 & USB interface
· AC and DC output selection to fulfill the test application needs in several power modes
· Comprehensive measurement of V, Irms, Ipk, W, VA, VAR, PF, CF of current etc.
· Memory and keypad lock functions with password setting 

 

 

 
 
MODEL
EAB-110 EAB-120 EAB-140 EAB-160
INPUT
Phase 1Ø or 3Ø
Voltage 100V - 240V±10% 200V - 240V±10% 1Ø / 3Ø3W: 200V - 240V±10%
3Ø4W: 346V - 416V±10%
Frequency 47 - 63Hz
Max. Current 15 30 30 1Ø:45A
3Ø3W:26A
3Ø4W:15A
Power Factor 0.97
AC OUTPUT
Max Power 1000VA 2000VA 4000VA 6000VA
Max Current 1Ø (r.m.s)*1 0-150V 9.2 A 18.4 A 36.8 A 55.2 A
0-300V 4.6 A 9.2 A 18.4 A 27.6A
Inrush Current (peak) 0-150V 36.8A 73.6A 147.2A 220.8A
0-300V 18.4A 36.8A 73.6A 110.4A
Phase 1Ø, (Linking Option 1Ø3W or 3Ø4W Poly-Phase)
Total Harmonic Distortion (THD) <0.5% (Resistive Load) at 40.0 - 70.0Hz and output voltage within the 80 - 140Vac at 
Low Range or the 160 - 280Vac at High Range
<1% (Resistive Load) at 70.1 - 500Hz and output voltage within the 80 - 140Vac at 
Low Range or the 160 - 280Vac at High Range
<1% (Resistive Load) at 501 - 1000Hz and output voltage within the 100 - 140Vac 
at Low Range or the 160 - 280Vac at High Range
Crest Factor ≧3
Line Regulation ± 0.1 V
Load Regulation ± (1% of output +1V) at Resistive Load
Response Time < 400 μsec
SETTINGS
Voltage Range 5 - 300V, 150 / 300V Auto Range
Resolution 0.1V
Accuracy ±(1% of setting + 2counts) ±(1% of setting + 5counts)
Frequency Range 40 - 1000Hz Full Range Adjust
Resolution 0.1Hz at 40.0 - 99.9Hz, 1Hz at 100 - 1000Hz
Accuracy ±0.03% of setting
Starting & Ending Range 0-359∘
Phase Angle Resolution 1∘
  Accuracy ±1∘(45 - 65HZ)
DC OUTPUT
Max Power 1000W 2000W 4000W 6000W
Max Current 0-210V 4.8A 9.6A 19.2A 28.8A
0-420V 2.4A 4.8A 9.6A 14.4A
Ripple & Noise (rms) Range L < 500mV < 700mV
H < 800mV < 1100mV
Ripple & Noise (p-p) < 3.0Vp-p < 4.0Vp-p
SETTINGS
Voltage Range 0 - 210V / 0 - 420V Selectable 0-210V / 0-420V Selectable >5V
Resolution 0.1V
Accuracy ± (1% of setting + 2 counts) ± (1% of setting + 5 counts)
Current Hi Limit Range L 0.01 - 4.80A 0.01 - 9.60A 0.10 - 19.20A 0.10 - 28.80A
(OC Fold=OFF) H 0.01 - 2.40A 0.01 - 4.80A 0.10 - 9.60A 0.10 - 14.40A
OC Fold Back Resolution 0.01 Amps
(OC Fold = ON) Accuracy ± (2.0% of setting + 2counts)
MEASUREMENT
Voltage Range 0 - 210V / 0 - 420V 0 - 210V / 0 - 420V Selectable >5V
Resolution 0.1 V
Accuracy ± (1% of reading + 2counts) ± (1% of reading + 5counts) > 5 V
Frequency Range 0.0 - 1000 Hz
Resolution 0.1 Hz
Accuracy ±0.1Hz (501 - 1000Hz Accuracy ± 0.2Hz)
Current (AC & DC) Range L 0.005 A - 1.200 A 0.005 A - 2.400 A - -
H 1.00 A - 13.00 A 2.00 A - 26.00 A 0.05 A - 52.00 A 0.05 A - 78.00 A
Resolution L 0.001A - -
H 0.01A
Accuracy L ± (1% of reading + 5counts)
H ± (1% of reading + 5 counts)
Current Peak Range 0.0A - 38.0 A 0.0 A - 76.0 A 0.0 A - 152.0 A 0.0 A - 228.0A
Resolution 0.1 A
Accuracy ± (1% of reading + 5 counts)
Power (AC) Range L 0.0 W - 120 W 0.0 W - 240 W - -
H 100 W - 1300 W 200 W - 2600 W 0 W - 5200 W 0 W - 7800 W
Resolution L 0.1W - -
H 1W
Accuracy L ± (2% of reading + 15counts ) at PF > 0.2 -
H ± (2% of reading + 5counts ) at PF > 0.2 ± (2% of reading + 10counts ) at PF > 0.2
Power (DC) Range L 0.0 W - 120 W 0.0 W - 240 W - -
H 100 W - 1300 W 200 W - 2600 W 0 W - 5200 W 0 W - 7800 W
Resolution L 0.1W - -
H 1W
Accuracy L ± (2% of reading +5counts)
H ± (2% of reading +5counts)
Power Apparent (VA) Range L 0.0VA - 120.0VA 0.0VA - 240.0VA - -
H 100VA - 1300VA 200VA - 2600VA 0VA - 5200VA 0VA - 7800VA
Resolution L 0.1VA - -
H 1VA
Accuracy V×A ,Calculated value
Power Resistive (Q) Range L 0.0VAR~120.0VAR 0.0VAR~240.0VAR - -
H 0VAR~1300VAR 0VAR~2600VAR 0VAR~5200VAR 0VAR~7800VAR
Resolution L 0.1VAR - -
H 1VAR
Bitmap
Accuracy
,Calculated value
Power Factor Range 0.000-1.000
Resolution 0.001
Accuracy W/VA, Calculated and displayed to three significant digits
Crest Factor Range 0 to 10.00
Resolution 0.01
Accuracy Apeak / Arms, Calculated and displayed to two significant digits
GENERAL
Transient (only for 40 - 70Hz) Trans-Volt:0.0 - 300.0V, Resolution: 0.1V
Trans-Site:0.0 - 25.0mS, Resolution: 0.1mS
Trans-Time:0.5 - 999.9mS, Resolution: 0.1mS
Trans-Cycle:0 - 9999, 0-Constant
Inrush Current 4 times current rating
Enhanced Over Load Capacity Over current 110% can hold for 1000 ms without protection
Operation Key Feature Soft key, Numeric key, Rotary Knob
Remote Input Signal (Option) Test, Reset, Recall program memory 1 through 7
Remote Output Signal Pass, Fail, Test-in-Process
Calibration Front Panel Calibration
Key Lock Yes, Password Driven
Synch Output Signal ON / Event / OFF, Output Signal 5V ,BNC type
Alarm Volume Setting Range: 0 - 9; 0=OFF, 1 is softest volume, 9 is loudest volume
Graphic Display 240 x 64 dot resolution Monographic LCD / Contrast 9 Levels 1-9
Interface (Option) Ethernet, USB / RS232, GPIB, Linking Card, PLC Remote Input Card
Protection Circuits OCP, OVP, OPP, OTP, RCP (Over Current, Over Voltage, Over Power, Over Temp)
Fan Temperature Control
Rear Output Terminal Block (L,N, G, Ls, Ns)
Rack mount Handles Yes
PFC PF≥ 0.97 at Full load
Effieciency ≥75% (at Full load) ≥80% (at Full load)
Auto loop cycle 0=Continuous, OFF, 2~9999
Over Current Fold Back On/Off , Setting On when output current over setting Hi-A value it will fold back output voltage to keep constant output current is setting Hi-A value
CE Mark Yes
Parallel Output for 1Ø Output Yes
Linking Output for 3Ø Output Yes
Operation Environment 0 - 40ºC / 20 - 80% RH
Dimension, mm*2 W 430 430 430 430
H 133.5 (148) 133.5 (148) 267 (281) 400.5 (473)
D 530 530 530 530
Net Weight 20Kg 21Kg 40Kg 53Kg
*1 At working voltage 110V / 220V
*2 Figure in parentheses are maximum values *product specifications are subject to change without notice.