모델명
according to DIN VDE 0281
Technical data
PVC-control cables to DIN VDE 0281 part 5 and IEC 60227-5, HD 21.5 S3
ㆍTemperature range
flexing - 5 ºC to + 70 ºC
fixed installation -40 ºC to + 70 ºC
ㆍNominal voltage Uo/ U 300/300V
ㆍMax. permissible operating voltage
in three - phase and one - phase
a.c. system Uo/ U 300/300V
in direct current system
Uo/ U 495/495 V
ㆍTest voltage 2000 V
ㆍBreakdown votage
min. 4000 V
ㆍInsulation resistance
min. 20 MOhm x km
ㆍMinimum bending radius
flexing 7.5x cable ø
ㆍRadiation resistance
up to 80x10 CJ/KG (up to 80 Mrad)
Cable structure
ㆍBare copper, fine wire conductors, bunch stranded to DIN CDE 0295 cl. 5, BS 6360 cl, 5, IEC 60228 cl, 5 and HD 383
ㆍPVC core insulation TI2 to DIN VDE 0281 part 1
ㆍCores colour coded to DIN CDE 0293-308 6and more cores number coded 1x green-yellow earth core incl.
ㆍGreen-yellow earth-core, 3 cores and above
ㆍCores stranded in layers with optimal lay-lengrh
ㆍPVC outer jacket in black, white or as per requirement
ㆍPVC outer jacket TM2 to DIN VDE 0281 part 1
Properties
ㆍPVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2/ IEC 60332-1 (equivalent DIN VDE 0472 part 804 test merhod B)
ㆍThe materials used in manufacture are cadmium - free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Note
ㆍG =With green - yellow earth core
x = Without green - yellow earth core
ㆍAWG sizes are approximate equivalent values. The actual cross - section is in mm2
ㆍ5 core and above in adaption (H).
ㆍ The above list contains a selection of the types we carry es stock. Other sizes acailable on request.